Dl4All Logo
Tutorials / Free Courses Graphics :

VRV VRF System Pipe Sizing

   Author: Baturi   |   18 August 2025   |   Comments icon: 0


Free Download VRV/VRF System Pipe Sizing
Published 8/2025
MP4 | Video: h264, 1280x720 | Audio: AAC, 44.1 KHz, 2 Ch
Language: English | Duration: 3h 4m | Size: 1.33 GB
Learn VRV Pipe Sizing- Manual & Software


What you'll learn
Basic of VRV/VRF System
VRV Equipment Selection
Pipe Sizing Manual
Pipe Sizing Software
Requirements
Basic Knowledge of HVAC
Description
Course Title:VRF / VRV System Design and Pipe Sizing (Daikin)Module 1 – IntroductionVRF (Variable Refrigerant Flow) definitionVRV (Variable Refrigerant Volume) definitionTerminology difference (VRV patented by Daikin)Applications & benefitsOne outdoor can connect >60 indoor unitsModule 2 – Components & RefrigerantsCompressors:Digital Scroll CompressorInverter Scroll CompressorRefrigerants: R-410A, R-407C, R-32, R-454BVFD (Variable Frequency Drive) operationPower frequency relation to compressor speedModule 3 – System TypesCooling Only VRFVariable speed scroll compressorElectronic Expansion Valve (EEV)Heat Pump VRFCooling or heating (not simultaneous)Uses 4-way Reversion Valve & NRVHeat Recovery VRF3-pipe systemCooling & heating simultaneouslyModule 4 – Capacity & Piping LimitsCapacity range: 3 TR to 42 TR (10 kW to 150 kW)Max piping length (Daikin example):150 m same level50 m ODU above IDU40 m ODU below IDUDaikin pipe sizing conditions:Max total length = 1000 mMax equivalent length = 190 mMax 13 m branch to last ODUMax 90 m from first indoor branch to farthest IDUMax level difference ODU–IDU = 90 mMax level difference IDUs = 30 mMax level difference ODUs = 5 mModule 5 – Diversity FactorConcept in VRF designNot all IDUs run at full load simultaneouslyExample: 20 HP total indoor load with 15 HP ODUModule 6 – Design Process (Daikin Example)1. Collect project requirements – building survey2. Perform heat load calculation (E-20 Excel, HAP)3. Select indoor units (IDUs)4. Select outdoor unit (ODU)5. Design refrigerant piping layout in AutoCAD6. Perform pipe sizing (manual or software)Module 7 – Pipe Sizing BasicsPurpose:Ensure correct refrigerant flowAvoid oil return issuesMaintain performance & efficiencyPipes: liquid, gas (suction), discharge (heat recovery)Refnet joints/Y-branch connectorsPipe sizing rules:Size increases after each branchDifferent for horizontal/verticalLong run adjustments (>40 m) require 1-step larger pipeModule 8 – Manual Pipe Sizing Steps (Daikin)1. Verify pipe conditions2. Find CI of indoor units & update on Refnet3. Size pipe between Refnet & IDU (Table 5)4. Size pipe from ODU to first Refnet (Table 9 or 10)5. Size pipe between Refnet to Refnet (Table 6 or 7)6. Select outdoor branch kit (Table 4)7. First Refnet from branch kit (Table 3)8. All other Refnet updates (Table 2)Module 9 – Common Issues from Wrong Pipe SizingPoor cooling/heatingOil return failure → compressor damageRefrigerant pressure drop → efficiency lossSystem alarms/trips
Who this course is for
Mechanical, Electrical, Engineers, Architect
Homepage
https://www.udemy.com/course/vrvvrf-system-pipe-sizing/






Buy Premium From My Links To Get Resumable Support,Max Speed & Support Me


No Password - Links are Interchangeable

Free VRV VRF System Pipe Sizing, Downloads VRV VRF System Pipe Sizing, Rapidgator VRV VRF System Pipe Sizing, Mega VRV VRF System Pipe Sizing, Torrent VRV VRF System Pipe Sizing, Google Drive VRV VRF System Pipe Sizing.
Feel free to post comments, reviews, or suggestions about VRV VRF System Pipe Sizing including tutorials, audio books, software, videos, patches, and more.

[related-news]



[/related-news]
DISCLAIMER
None of the files shown here are hosted or transmitted by this server. The links are provided solely by this site's users. The administrator of our site cannot be held responsible for what its users post, or any other actions of its users. You may not use this site to distribute or download any material when you do not have the legal rights to do so. It is your own responsibility to adhere to these terms.

Copyright © 2018 - 2025 Dl4All. All rights reserved.